The Software-RAID HOWTO
  Jakob OEstergaard (jakob@ostenfeld.dk)
  v. 0.90.7 19th of January 2000

  This HOWTO describes how to use Software RAID under Linux. It
  addresses a specific version of the Software RAID layer, namely the
  0.90 RAID layer made by Ingo Molnar and others. This is the RAID layer
  that will be standard in Linux-2.4, and it is the version that is also
  used by Linux-2.2 kernels shipped from some vendors. The 0.90 RAID
  support is available as patches to Linux-2.0 and Linux-2.2, and is by
  many considered far more stable that the older RAID support already in
  those kernels.
  ______________________________________________________________________

  Table of Contents



  1. Introduction

     1.1 Disclaimer
     1.2 Requirements

  2. Why RAID ?

     2.1 Technicalities
     2.2 Terms
     2.3 The RAID levels
        2.3.1 Spare disks
     2.4 Swapping on RAID

  3. Hardware issues

     3.1 IDE Configuration
     3.2 Hot Swap
        3.2.1 Hot-swapping IDE drives
        3.2.2 Hot-swapping SCSI drives
        3.2.3 Hot-swapping with SCA

  4. RAID setup

     4.1 General setup
     4.2 Linear mode
     4.3 RAID-0
     4.4 RAID-1
     4.5 RAID-4
     4.6 RAID-5
     4.7 The Persistent Superblock
     4.8 Chunk sizes
        4.8.1 RAID-0
        4.8.2 RAID-1
        4.8.3 RAID-4
        4.8.4 RAID-5
     4.9 Options for mke2fs
     4.10 Autodetection
     4.11 Booting on RAID
     4.12 Root filesystem on RAID
        4.12.1 Method 1
        4.12.2 Method 2
     4.13 Making the system boot on RAID
        4.13.1 Booting with RAID as module
     4.14 Pitfalls

  5. Testing

     5.1 Simulating a drive failure
     5.2 Simulating data corruption

  6. Reconstruction

     6.1 Recovery from a multiple disk failure

  7. Performance

     7.1 RAID-0
     7.2 RAID-0 with TCQ
     7.3 RAID-5
     7.4 RAID-10

  8. Credits



  ______________________________________________________________________

  1.  Introduction

  For a description of the older RAID layer, the one which is standard
  in 2.0 and 2.2 kernels, see the excellent HOWTO from Linas Vepstas
  (linas@linas.org) available from the Linux Documentation Project at
  linuxdoc.org.

  The home site for this HOWTO is http://ostenfeld.dk/~jakob/Software-
  RAID.HOWTO/, where updated versions appear first.  The howto is
  written by Jakob OEstergaard based on a large number of emails between
  the author and Ingo Molnar (mingo@chiara.csoma.elte.hu) -- one of the
  RAID developers --, the linux-raid mailing list (linux-
  raid@vger.rutgers.edu) and various other people.

  The reason this HOWTO was written even though a Software-RAID HOWTO
  already exists is, that the old HOWTO describes the old-style Software
  RAID found in the standard 2.0 and 2.2 kernels. This HOWTO describes
  the use of the new-style RAID that has been developed more recently.
  The new-style RAID has a lot of features not present in old-style
  RAID.

  If you want to use the new-style RAID with 2.0 or 2.2 kernels, you
  should get a patch for your kernel, either from ftp://ftp.[your-
  country-code].kernel.org/pub/linux/daemons/raid/alpha, or more
  recently from http://people.redhat.com/mingo/ The standard 2.2 kernels
  does not have direct support for the new-style RAID described in this
  HOWTO.  Therefore these patches are needed.  The old-style RAID
  support in standard 2.0 and 2.2 kernels is buggy and lacks several
  important features present in the new-style RAID software.

  As of this writing, the new-style RAID support is being merged into
  the 2.3 development kernels, and will therefore (most likely) be
  present in the 2.4 Linux kernel when that one comes out. But until
  then, the stable kernels must be patched manually.

  You might want to use the -ac kernel releases done by Alan Cox, for
  RAID support in 2.2.  Some of those contain the new-style RAID, and
  that will save you from patching the kernel yourself.

  Some of the information in this HOWTO may seem trivial, if you know
  RAID all ready. Just skip those parts.



  1.1.  Disclaimer

  The mandatory disclaimer:

  Although RAID seems stable for me, and stable for many other people,
  it may not work for you.  If you lose all your data, your job, get hit
  by a truck, whatever, it's not my fault, nor the developers'.  Be
  aware, that you use the RAID software and this information at your own
  risk!  There is no guarantee whatsoever, that any of the software, or
  this information, is in anyway correct, nor suited for any use
  whatsoever. Back up all your data before experimenting with this.
  Better safe than sorry.

  That said, I must also say that I haven't had a single stability
  problem with Software RAID, I use it on quite a few machines with no
  problems what so ever, and I haven't seen other people having problems
  with random crashes or instability caused by RAID.



  1.2.  Requirements

  This HOWTO assumes you are using a late 2.2.x or 2.0.x kernel with a
  matching raid0145 patch and the 0.90 version of the raidtools, or that
  you are using a late 2.3 kernel (version > 2.3.46) or eventually 2.4.
  Both the patches and the tools can be found at
  ftp://ftp.fi.kernel.org/pub/linux/daemons/raid/alpha, and in some
  cases at http://people.redhat.com/mingo/. The RAID patch, the
  raidtools package, and the kernel should all match as close as
  possible. At times it can be necessary to use older kernels if raid
  patches are not available for the latest kernel.



  2.  Why RAID ?

  There can be many good reasons for using RAID. A few are; the ability
  to combine several physical disks into one larger ``virtual'' device,
  performance improvements, and redundancy.



  2.1.  Technicalities

  Linux RAID can work on most block devices. It doesn't matter whether
  you use IDE or SCSI devices, or a mixture. Some people have also used
  the Network Block Device (NBD) with more or less success.

  Be sure that the bus(ses) to the drives are fast enough. You shouldn't
  have 14 UW-SCSI drives on one UW bus, if each drive can give 10 MB/s
  and the bus can only sustain 40 MB/s.  Also, you should only have one
  device per IDE bus. Running disks as master/slave is horrible for
  performance. IDE is really bad at accessing more that one drive per
  bus.  Of Course, all newer motherboards have two IDE busses, so you
  can set up two disks in RAID without buying more controllers.

  The RAID layer has absolutely nothing to do with the filesystem layer.
  You can put any filesystem on a RAID device, just like any other block
  device.



  2.2.  Terms

  The word ``RAID'' means ``Linux Software RAID''. This HOWTO does not
  treat any aspects of Hardware RAID.

  When describing setups, it is useful to refer to the number of disks
  and their sizes. At all times the letter N is used to denote the
  number of active disks in the array (not counting spare-disks). The
  letter S is the size of the smallest drive in the array, unless
  otherwise mentioned. The letter P is used as the performance of one
  disk in the array, in MB/s. When used, we assume that the disks are
  equally fast, which may not always be true.

  Note that the words ``device'' and ``disk'' are supposed to mean about
  the same thing.  Usually the devices that are used to build a RAID
  device are partitions on disks, not necessarily entire disks.  But
  combining several partitions on one disk usually does not make sense,
  so the words devices and disks just mean ``partitions on different
  disks''.



  2.3.  The RAID levels

  Here's a short description of what is supported in the Linux RAID
  patches. Some of this information is absolutely basic RAID info, but
  I've added a few notices about what's special in the Linux
  implementation of the levels.  Just skip this section if you know
  RAID. Then come back when you are having problems   :)

  The current RAID patches for Linux supports the following levels:

  o  Linear mode

  o  Two or more disks are combined into one physical device. The disks
     are ``appended'' to each other, so writing to the RAID device will
     fill up disk 0 first, then disk 1 and so on. The disks does not
     have to be of the same size. In fact, size doesn't matter at all
     here   :)

  o  There is no redundancy in this level. If one disk crashes you will
     most probably lose all your data.  You can however be lucky to
     recover some data, since the filesystem will just be missing one
     large consecutive chunk of data.

  o  The read and write performance will not increase for single
     reads/writes. But if several users use the device, you may be lucky
     that one user effectively is using the first disk, and the other
     user is accessing files which happen to reside on the second disk.
     If that happens, you will see a performance gain.

  o  RAID-0

  o  Also called ``stripe'' mode. Like linear mode, except that reads
     and writes are done in parallel to the devices. The devices should
     have approximately the same size. Since all access is done in
     parallel, the devices fill up equally. If one device is much larger
     than the other devices, that extra space is still utilized in the
     RAID device, but you will be accessing this larger disk alone,
     during writes in the high end of your RAID device. This of course
     hurts performance.

  o  Like linear, there's no redundancy in this level either. Unlike
     linear mode, you will not be able to rescue any data if a drive
     fails. If you remove a drive from a RAID-0 set, the RAID device
     will not just miss one consecutive block of data, it will be filled
     with small holes all over the device. e2fsck will probably not be
     able to recover much from such a device.

  o  The read and write performance will increase, because reads and
     writes are done in parallel on the devices. This is usually the
     main reason for running RAID-0. If the busses to the disks are fast
     enough, you can get very close to N*P MB/sec.

  o  RAID-1

  o  This is the first mode which actually has redundancy. RAID-1 can be
     used on two or more disks with zero or more spare-disks. This mode
     maintains an exact mirror of the information on one disk on the
     other disk(s). Of Course, the disks must be of equal size. If one
     disk is larger than another, your RAID device will be the size of
     the smallest disk.

  o  If up to N-1 disks are removed (or crashes), all data are still
     intact. If there are spare disks available, and if the system (eg.
     SCSI drivers or IDE chipset etc.) survived the crash,
     reconstruction of the mirror will immediately begin on one of the
     spare disks, after detection of the drive fault.
  o  Write performance is the slightly worse than on a single device,
     because identical copies of the data written must be sent to every
     disk in the array.  Read performance is usually pretty bad because
     of an oversimplified read-balancing strategy in the RAID code.
     However, there has been implemented a much improved read-balancing
     strategy, which might be available for the Linux-2.2 RAID patches
     (ask on the linux-kernel list), and which will most likely be in
     the standard 2.4 kernel RAID support.

  o  RAID-4

  o  This RAID level is not used very often. It can be used on three or
     more disks. Instead of completely mirroring the information, it
     keeps parity information on one drive, and writes data to the other
     disks in a RAID-0 like way.  Because one disks is reserved for
     parity information, the size of the array will be (N-1)*S, where S
     is the size of the smallest drive in the array. As in RAID-1, the
     disks should either be of equal size, or you will just have to
     accept that the S in the (N-1)*S formula above will be the size of
     the smallest drive in the array.

  o  If one drive fails, the parity information can be used to
     reconstruct all data.  If two drives fail, all data is lost.

  o  The reason this level is not more frequently used, is because the
     parity information is kept on one drive. This information must be
     updated every time one of the other disks are written to. Thus, the
     parity disk will become a bottleneck, if it is not a lot faster
     than the other disks.  However, if you just happen to have a lot of
     slow disks and a very fast one, this RAID level can be very useful.

  o  RAID-5

  o  This is perhaps the most useful RAID mode when one wishes to
     combine a larger number of physical disks, and still maintain some
     redundancy. RAID-5 can be used on three or more disks, with zero or
     more spare-disks. The resulting RAID-5 device size will be (N-1)*S,
     just like RAID-4. The big difference between RAID-5 and -4 is, that
     the parity information is distributed evenly among the
     participating drives, avoiding the bottleneck problem in RAID-4.

  o  If one of the disks fail, all data are still intact, thanks to the
     parity information. If spare disks are available, reconstruction
     will begin immediately after the device failure.  If two disks fail
     simultaneously, all data are lost. RAID-5 can survive one disk
     failure, but not two or more.

  o  Both read and write performance usually increase, but it's hard to
     predict how much.


  2.3.1.  Spare disks

  Spare disks are disks that do not take part in the RAID set until one
  of the active disks fail.  When a device failure is detected, that
  device is marked as ``bad'' and reconstruction is immediately started
  on the first spare-disk available.

  Thus, spare disks add a nice extra safety to especially RAID-5 systems
  that perhaps are hard to get to (physically). One can allow the system
  to run for some time, with a faulty device, since all redundancy is
  preserved by means of the spare disk.

  You cannot be sure that your system will survive a disk crash. The
  RAID layer should handle device failures just fine, but SCSI drivers
  could be broken on error handling, or the IDE chipset could lock up,
  or a lot of other things could happen.



  2.4.  Swapping on RAID

  There's no reason to use RAID for swap performance reasons. The kernel
  itself can stripe swapping on several devices, if you just give them
  the same priority in the fstab file.

  A nice fstab looks like:

  /dev/sda2       swap           swap    defaults,pri=1   0 0
  /dev/sdb2       swap           swap    defaults,pri=1   0 0
  /dev/sdc2       swap           swap    defaults,pri=1   0 0
  /dev/sdd2       swap           swap    defaults,pri=1   0 0
  /dev/sde2       swap           swap    defaults,pri=1   0 0
  /dev/sdf2       swap           swap    defaults,pri=1   0 0
  /dev/sdg2       swap           swap    defaults,pri=1   0 0


  This setup lets the machine swap in parallel on seven SCSI devices. No
  need for RAID, since this has been a kernel feature for a long time.

  Another reason to use RAID for swap is high availability.  If you set
  up a system to boot on eg. a RAID-1 device, the system should be able
  to survive a disk crash. But if the system has been swapping on the
  now faulty device, you will for sure be going down.  Swapping on the
  RAID-1 device would solve this problem.

  There has been a lot of discussion about whether swap was stable on
  RAID devices. This is a continuing debate, because it depends highly
  on other aspects of the kernel as well.  As of this writing, it seems
  that swapping on RAID should be perfectly stable, except for when the
  array is reconstructing (eg. after a new disk is inserted into a
  degraded array). When 2.4 comes out this is an issue that will most
  likely get addressed fairly quickly, but until then, you should
  stress-test the system yourself until you are either satisfied with
  the stability or conclude that you won't be swapping on RAID.

  You can set up RAID in a swap file on a filesystem on your RAID
  device, or you can set up a RAID device as a swap partition, as you
  see fit.  As usual, the RAID device is just a block device.



  3.  Hardware issues

  This section will mention some of the hardware concerns involved when
  running software RAID.


  3.1.  IDE Configuration

  It is indeed possible to run RAID over IDE disks. And excellent
  performance can be achieved too. In fact, today's price on IDE drives
  and controllers does make IDE something to be considered, when setting
  up new RAID systems.

  o  Physical stability: IDE drives has traditionally been of lower
     mechanical quality than SCSI drives. Even today, the warranty on
     IDE drives is typically one year, whereas it is often three to five
     years on SCSI drives.  Although it is not fair to say, that IDE
     drives are per definition poorly made, one should be aware that IDE
     drives of some brand may fail more often that similar SCSI drives.
     However, other brands use the exact same mechanical setup for both
     SCSI and IDE drives. It all boils down to: All disks fail, sooner
     or later, and one should be prepared for that.

  o  Data integrity: Earlier, IDE had no way of assuring that the data
     sent onto the IDE bus would be the same as the data actually
     written to the disk. This was due to total lack of parity,
     checksums, etc.  With the Ultra-DMA standard, IDE drives now do a
     checksum on the data they receive, and thus it becomes highly
     unlikely that data get corrupted.

  o  Performance: I'm not going to write thoroughly about IDE
     performance here. The really short story is:

  o  IDE drives are fast (12 MB/s and beyond)

  o  IDE has more CPU overhead than SCSI (but who cares?)

  o  Only use one IDE drive per IDE bus, slave disks spoil performance

  o  Fault survival: The IDE driver usually survives a failing IDE
     device. The RAID layer will mark the disk as failed, and if you are
     running RAID levels 1 or above, the machine should work just fine
     until you can take it down for maintenance.

  It is very important, that you only use one IDE disk per IDE bus. Not
  only would two disks ruin the performance, but the failure of a disk
  often guarantees the failure of the bus, and therefore the failure of
  all disks on that bus.  In a fault-tolerant RAID setup (RAID levels
  1,4,5), the failure of one disk can be handled, but the failure of two
  disks (the two disks on the bus that fails due to the failure of the
  one disk) will render the array unusable. Also, when the master drive
  on a bus fails, the slave or the IDE controller may get awfully
  confused. One bus, one drive, that's the rule.

  There are cheap PCI IDE controllers out there. You often get two or
  four busses for around $80. Considering the much lower price of IDE
  disks versus SCSI disks, I'd say an IDE disk array could be a really
  nice solution if one can live with the relatively low (around 8
  probably) disks one can attach to a typical system (unless of course,
  you have a lot of PCI slots for those IDE controllers).

  IDE has major cabling problems though when it comes to large arrays.
  Even if you had enough PCI slots, it's unlikely that you could fit
  much more than 8 disks in a system and still get it running without
  data corruption (caused by too long IDE cables).



  3.2.  Hot Swap

  This has been a hot topic on the linux-kernel list for some time.
  Although hot swapping of drives is supported to some extent, it is
  still not something one can do easily.


  3.2.1.  Hot-swapping IDE drives

  Don't ! IDE doesn't handle hot swapping at all.  Sure, it may work for
  you, if your IDE driver is compiled as a module (only possible in the
  2.2 series of the kernel), and you re-load it after you've replaced
  the drive.  But you may just as well end up with a fried IDE
  controller, and you'll be looking at a lot more down-time than just
  the time it would have taken to replace the drive on a downed system.


  The main problem, except for the electrical issues that can destroy
  your hardware, is that the IDE bus must be re-scanned after disks are
  swapped. The current IDE driver can't do that.  If the new disk is
  100% identical to the old one (wrt. geometry etc.), it may work even
  without re-scanning the bus, but really, you're walking the bleeding
  edge here.


  3.2.2.  Hot-swapping SCSI drives

  Normal SCSI hardware is not hot-swappable either. It may however work.
  If your SCSI driver supports re-scanning the bus, and removing and
  appending devices, you may be able to hot-swap devices. However, on a
  normal SCSI bus you probably shouldn't unplug devices while your
  system is still powered up. But then again, it may just work (and you
  may end up with fried hardware).

  The SCSI layer should survive if a disk dies, but not all SCSI drivers
  handle this yet. If your SCSI driver dies when a disk goes down, your
  system will go with it, and hot-plug isn't really interesting then.


  3.2.3.  Hot-swapping with SCA

  With SCA, it should be possible to hot-plug devices. However, I don't
  have the hardware to try this out, and I haven't heard from anyone
  who's tried, so I can't really give any recipe on how to do this.

  If you want to play with this, you should know about SCSI and RAID
  internals anyway. So I'm not going to write something here that I
  can't verify works, instead I can give a few clues:

  o  Grep for remove-single-device in linux/drivers/scsi/scsi.c

  o  Take a look at raidhotremove and raidhotadd

  Not all SCSI drivers support appending and removing devices. In the
  2.2 series of the kernel, at least the Adaptec 2940 and Symbios
  NCR53c8xx drivers seem to support this, others may and may not. I'd
  appreciate if anyone has additional facts here...



  4.  RAID setup


  4.1.  General setup

  This is what you need for any of the RAID levels:

  o  A kernel. Preferably a stable 2.2.X kernel, or the latest 2.0.X.
     (If 2.4 is out when you read this, go for that one instead)

  o  The RAID patches.  There usually is a patch available for the
     recent kernels. (If you found a 2.4 kernel, the patches are already
     in and you can forget about them)

  o  The RAID tools.

  o  Patience, Pizza, and your favorite caffeinated beverage.

  All this software can be found at ftp://ftp.fi.kernel.org/pub/linux
  The RAID tools and patches are in the daemons/raid/alpha subdirectory.
  The kernels are found in the kernel subdirectory.

  Patch the kernel, configure it to include RAID support for the level
  you want to use.  Compile it and install it.

  Then unpack, configure, compile and install the RAID tools.

  Ok, so far so good.  If you reboot now, you should have a file called
  /proc/mdstat.  Remember it, that file is your friend. See what it
  contains, by doing a cat /proc/mdstat. It should tell you that you
  have the right RAID personality (eg. RAID mode) registered, and that
  no RAID devices are currently active.

  Create the partitions you want to include in your RAID set.

  Now, let's go mode-specific.



  4.2.  Linear mode

  Ok, so you have two or more partitions which are not necessarily the
  same size (but of course can be), which you want to append to each
  other.

  Set up the /etc/raidtab file to describe your setup. I set up a
  raidtab for two disks in linear mode, and the file looked like this:


  raiddev /dev/md0
          raid-level      linear
          nr-raid-disks   2
          chunk-size      32
          persistent-superblock 1
          device          /dev/sdb6
          raid-disk       0
          device          /dev/sdc5
          raid-disk       1


  Spare-disks are not supported here.  If a disk dies, the array dies
  with it. There's no information to put on a spare disk.

  You're probably wondering why we specify a chunk-size here when linear
  mode just appends the disks into one large array with no parallelism.
  Well, you're completely right, it's odd. Just put in some chunk size
  and don't worry about this any more.

  Ok, let's create the array. Run the command

    mkraid /dev/md0



  This will initialize your array, write the persistent superblocks, and
  start the array.

  Have a look in /proc/mdstat. You should see that the array is running.

  Now, you can create a filesystem, just like you would on any other
  device, mount it, include it in your fstab and so on.



  4.3.  RAID-0

  You have two or more devices, of approximately the same size, and you
  want to combine their storage capacity and also combine their
  performance by accessing them in parallel.

  Set up the /etc/raidtab file to describe your configuration. An
  example raidtab looks like:

  raiddev /dev/md0
          raid-level      0
          nr-raid-disks   2
          persistent-superblock 1
          chunk-size     4
          device          /dev/sdb6
          raid-disk       0
          device          /dev/sdc5
          raid-disk       1


  Like in Linear mode, spare disks are not supported here either. RAID-0
  has no redundancy, so when a disk dies, the array goes with it.

  Again, you just run

    mkraid /dev/md0


  to initialize the array. This should initialize the superblocks and
  start the raid device.  Have a look in /proc/mdstat to see what's
  going on. You should see that your device is now running.

  /dev/md0 is now ready to be formatted, mounted, used and abused.



  4.4.  RAID-1

  You have two devices of approximately same size, and you want the two
  to be mirrors of each other. Eventually you have more devices, which
  you want to keep as stand-by spare-disks, that will automatically
  become a part of the mirror if one of the active devices break.

  Set up the /etc/raidtab file like this:

  raiddev /dev/md0
          raid-level      1
          nr-raid-disks   2
          nr-spare-disks  0
          chunk-size     4
          persistent-superblock 1
          device          /dev/sdb6
          raid-disk       0
          device          /dev/sdc5
          raid-disk       1


  If you have spare disks, you can add them to the end of the device
  specification like

          device          /dev/sdd5
          spare-disk      0


  Remember to set the nr-spare-disks entry correspondingly.

  Ok, now we're all set to start initializing the RAID. The mirror must
  be constructed, eg. the contents (however unimportant now, since the
  device is still not formatted) of the two devices must be
  synchronized.
  Issue the

    mkraid /dev/md0


  command to begin the mirror initialization.

  Check out the /proc/mdstat file. It should tell you that the /dev/md0
  device has been started, that the mirror is being reconstructed, and
  an ETA of the completion of the reconstruction.

  Reconstruction is done using idle I/O bandwidth. So, your system
  should still be fairly responsive, although your disk LEDs should be
  glowing nicely.

  The reconstruction process is transparent, so you can actually use the
  device even though the mirror is currently under reconstruction.

  Try formatting the device, while the reconstruction is running. It
  will work.  Also you can mount it and use it while reconstruction is
  running. Of Course, if the wrong disk breaks while the reconstruction
  is running, you're out of luck.



  4.5.  RAID-4

  Note! I haven't tested this setup myself. The setup below is my best
  guess, not something I have actually had up running.

  You have three or more devices of roughly the same size, one device is
  significantly faster than the other devices, and you want to combine
  them all into one larger device, still maintaining some redundancy
  information.  Eventually you have a number of devices you wish to use
  as spare-disks.

  Set up the /etc/raidtab file like this:

  raiddev /dev/md0
          raid-level      4
          nr-raid-disks   4
          nr-spare-disks  0
          persistent-superblock 1
          chunk-size      32
          device          /dev/sdb1
          raid-disk       0
          device          /dev/sdc1
          raid-disk       1
          device          /dev/sdd1
          raid-disk       2
          device          /dev/sde1
          raid-disk       3


  If we had any spare disks, they would be inserted in a similar way,
  following the raid-disk specifications;

          device         /dev/sdf1
          spare-disk     0


  as usual.

  Your array can be initialized with the


     mkraid /dev/md0


  command as usual.

  You should see the section on special options for mke2fs before
  formatting the device.



  4.6.  RAID-5

  You have three or more devices of roughly the same size, you want to
  combine them into a larger device, but still to maintain a degree of
  redundancy for data safety. Eventually you have a number of devices to
  use as spare-disks, that will not take part in the array before
  another device fails.

  If you use N devices where the smallest has size S, the size of the
  entire array will be (N-1)*S. This ``missing'' space is used for
  parity (redundancy) information.  Thus, if any disk fails, all data
  stay intact. But if two disks fail, all data is lost.

  Set up the /etc/raidtab file like this:

  raiddev /dev/md0
          raid-level      5
          nr-raid-disks   7
          nr-spare-disks  0
          persistent-superblock 1
          parity-algorithm        left-symmetric
          chunk-size      32
          device          /dev/sda3
          raid-disk       0
          device          /dev/sdb1
          raid-disk       1
          device          /dev/sdc1
          raid-disk       2
          device          /dev/sdd1
          raid-disk       3
          device          /dev/sde1
          raid-disk       4
          device          /dev/sdf1
          raid-disk       5
          device          /dev/sdg1
          raid-disk       6


  If we had any spare disks, they would be inserted in a similar way,
  following the raid-disk specifications;

          device         /dev/sdh1
          spare-disk     0


  And so on.

  A chunk size of 32 KB is a good default for many general purpose
  filesystems of this size. The array on which the above raidtab is
  used, is a 7 times 6 GB = 36 GB (remember the (n-1)*s = (7-1)*6 = 36)
  device. It holds an ext2 filesystem with a 4 KB block size.  You could
  go higher with both array chunk-size and filesystem block-size if your
  filesystem is either much larger, or just holds very large files.


  Ok, enough talking. You set up the raidtab, so let's see if it works.
  Run the

    mkraid /dev/md0


  command, and see what happens.  Hopefully your disks start working
  like mad, as they begin the reconstruction of your array. Have a look
  in /proc/mdstat to see what's going on.

  If the device was successfully created, the reconstruction process has
  now begun.  Your array is not consistent until this reconstruction
  phase has completed. However, the array is fully functional (except
  for the handling of device failures of course), and you can format it
  and use it even while it is reconstructing.

  See the section on special options for mke2fs before formatting the
  array.

  Ok, now when you have your RAID device running, you can always stop it
  or re-start it using the

    raidstop /dev/md0


  or

    raidstart /dev/md0


  commands.

  Instead of putting these into init-files and rebooting a zillion times
  to make that work, read on, and get autodetection running.



  4.7.  The Persistent Superblock

  Back in ``The Good Old Days'' (TM), the raidtools would read your
  /etc/raidtab file, and then initialize the array.  However, this would
  require that the filesystem on which /etc/raidtab resided was mounted.
  This is unfortunate if you want to boot on a RAID.

  Also, the old approach led to complications when mounting filesystems
  on RAID devices. They could not be put in the /etc/fstab file as
  usual, but would have to be mounted from the init-scripts.

  The persistent superblocks solve these problems. When an array is
  initialized with the persistent-superblock option in the /etc/raidtab
  file, a special superblock is written in the beginning of all disks
  participating in the array. This allows the kernel to read the
  configuration of RAID devices directly from the disks involved,
  instead of reading from some configuration file that may not be
  available at all times.

  You should however still maintain a consistent /etc/raidtab file,
  since you may need this file for later reconstruction of the array.

  The persistent superblock is mandatory if you want auto-detection of
  your RAID devices upon system boot. This is described in the
  Autodetection section.



  4.8.  Chunk sizes

  The chunk-size deserves an explanation.  You can never write
  completely parallel to a set of disks. If you had two disks and wanted
  to write a byte, you would have to write four bits on each disk,
  actually, every second bit would go to disk 0 and the others to disk
  1. Hardware just doesn't support that.  Instead, we choose some chunk-
  size, which we define as the smallest ``atomic'' mass of data that can
  be written to the devices.  A write of 16 KB with a chunk size of 4
  KB, will cause the first and the third 4 KB chunks to be written to
  the first disk, and the second and fourth chunks to be written to the
  second disk, in the RAID-0 case with two disks.  Thus, for large
  writes, you may see lower overhead by having fairly large chunks,
  whereas arrays that are primarily holding small files may benefit more
  from a smaller chunk size.

  Chunk sizes must be specified for all RAID levels, including linear
  mode. However, the chunk-size does not make any difference for linear
  mode.

  For optimal performance, you should experiment with the value, as well
  as with the block-size of the filesystem you put on the array.

  The argument to the chunk-size option in /etc/raidtab specifies the
  chunk-size in kilobytes. So ``4'' means ``4 KB''.


  4.8.1.  RAID-0

  Data is written ``almost'' in parallel to the disks in the array.
  Actually, chunk-size bytes are written to each disk, serially.

  If you specify a 4 KB chunk size, and write 16 KB to an array of three
  disks, the RAID system will write 4 KB to disks 0, 1 and 2, in
  parallel, then the remaining 4 KB to disk 0.

  A 32 KB chunk-size is a reasonable starting point for most arrays. But
  the optimal value depends very much on the number of drives involved,
  the content of the file system you put on it, and many other factors.
  Experiment with it, to get the best performance.


  4.8.2.  RAID-1

  For writes, the chunk-size doesn't affect the array, since all data
  must be written to all disks no matter what.  For reads however, the
  chunk-size specifies how much data to read serially from the
  participating disks.  Since all active disks in the array contain the
  same information, reads can be done in a parallel RAID-0 like manner.


  4.8.3.  RAID-4

  When a write is done on a RAID-4 array, the parity information must be
  updated on the parity disk as well. The chunk-size is the size of the
  parity blocks. If one byte is written to a RAID-4 array, then chunk-
  size bytes will be read from the N-1 disks, the parity information
  will be calculated, and chunk-size bytes written to the parity disk.

  The chunk-size affects read performance in the same way as in RAID-0,
  since reads from RAID-4 are done in the same way.



  4.8.4.  RAID-5

  On RAID-5 the chunk-size has exactly the same meaning as in RAID-4.

  A reasonable chunk-size for RAID-5 is 128 KB, but as always, you may
  want to experiment with this.

  Also see the section on special options for mke2fs.  This affects
  RAID-5 performance.



  4.9.  Options for mke2fs

  There is a special option available when formatting RAID-4 or -5
  devices with mke2fs. The -R stride=nn option will allow mke2fs to
  better place different ext2 specific data-structures in an intelligent
  way on the RAID device.

  If the chunk-size is 32 KB, it means, that 32 KB of consecutive data
  will reside on one disk. If we want to build an ext2 filesystem with 4
  KB block-size, we realize that there will be eight filesystem blocks
  in one array chunk. We can pass this information on the mke2fs
  utility, when creating the filesystem:

    mke2fs -b 4096 -R stride=8 /dev/md0



  RAID-{4,5} performance is severely influenced by this option. I am
  unsure how the stride option will affect other RAID levels. If anyone
  has information on this, please send it in my direction.

  The ext2fs blocksize severely influences the performance of the
  filesystem. You should always use 4KB block size on any filesystem
  larger than a few hundred megabytes, unless you store a very large
  number of very small files on it.



  4.10.  Autodetection

  Autodetection allows the RAID devices to be automatically recognized
  by the kernel at boot-time, right after the ordinary partition
  detection is done.

  This requires several things:

  1. You need autodetection support in the kernel. Check this

  2. You must have created the RAID devices using persistent-superblock

  3. The partition-types of the devices used in the RAID must be set to
     0xFD  (use fdisk and set the type to ``fd'')

  NOTE: Be sure that your RAID is NOT RUNNING before changing the
  partition types.  Use raidstop /dev/md0 to stop the device.

  If you set up 1, 2 and 3 from above, autodetection should be set up.
  Try rebooting.  When the system comes up, cat'ing /proc/mdstat should
  tell you that your RAID is running.

  During boot, you could see messages similar to these:



   Oct 22 00:51:59 malthe kernel: SCSI device sdg: hdwr sector= 512
    bytes. Sectors= 12657717 [6180 MB] [6.2 GB]
   Oct 22 00:51:59 malthe kernel: Partition check:
   Oct 22 00:51:59 malthe kernel:  sda: sda1 sda2 sda3 sda4
   Oct 22 00:51:59 malthe kernel:  sdb: sdb1 sdb2
   Oct 22 00:51:59 malthe kernel:  sdc: sdc1 sdc2
   Oct 22 00:51:59 malthe kernel:  sdd: sdd1 sdd2
   Oct 22 00:51:59 malthe kernel:  sde: sde1 sde2
   Oct 22 00:51:59 malthe kernel:  sdf: sdf1 sdf2
   Oct 22 00:51:59 malthe kernel:  sdg: sdg1 sdg2
   Oct 22 00:51:59 malthe kernel: autodetecting RAID arrays
   Oct 22 00:51:59 malthe kernel: (read) sdb1's sb offset: 6199872
   Oct 22 00:51:59 malthe kernel: bind<sdb1,1>
   Oct 22 00:51:59 malthe kernel: (read) sdc1's sb offset: 6199872
   Oct 22 00:51:59 malthe kernel: bind<sdc1,2>
   Oct 22 00:51:59 malthe kernel: (read) sdd1's sb offset: 6199872
   Oct 22 00:51:59 malthe kernel: bind<sdd1,3>
   Oct 22 00:51:59 malthe kernel: (read) sde1's sb offset: 6199872
   Oct 22 00:51:59 malthe kernel: bind<sde1,4>
   Oct 22 00:51:59 malthe kernel: (read) sdf1's sb offset: 6205376
   Oct 22 00:51:59 malthe kernel: bind<sdf1,5>
   Oct 22 00:51:59 malthe kernel: (read) sdg1's sb offset: 6205376
   Oct 22 00:51:59 malthe kernel: bind<sdg1,6>
   Oct 22 00:51:59 malthe kernel: autorunning md0
   Oct 22 00:51:59 malthe kernel: running: <sdg1><sdf1><sde1><sdd1><sdc1><sdb1>
   Oct 22 00:51:59 malthe kernel: now!
   Oct 22 00:51:59 malthe kernel: md: md0: raid array is not clean --
    starting background reconstruction


  This is output from the autodetection of a RAID-5 array that was not
  cleanly shut down (eg. the machine crashed).  Reconstruction is auto-
  matically initiated.  Mounting this device is perfectly safe, since
  reconstruction is transparent and all data are consistent (it's only
  the parity information that is inconsistent - but that isn't needed
  until a device fails).

  Autostarted devices are also automatically stopped at shutdown.  Don't
  worry about init scripts.  Just use the /dev/md devices as any other
  /dev/sd or /dev/hd devices.

  Yes, it really is that easy.

  You may want to look in your init-scripts for any raidstart/raidstop
  commands. These are often found in the standard RedHat init scripts.
  They are used for old-style RAID, and has no use in new-style RAID
  with autodetection. Just remove the lines, and everything will be just
  fine.



  4.11.  Booting on RAID

  There are several ways to set up a system that mounts it's root
  filesystem on a RAID device.  At the moment, only the graphical
  install of RedHat Linux 6.1 allows direct installation to a RAID
  device.  So most likely you're in for a little tweaking if you want
  this, but it is indeed possible.

  The latest official lilo distribution (Version 21) doesn't handle RAID
  devices, and thus the kernel cannot be loaded at boot-time from a RAID
  device. If you use this version, your /boot filesystem will have to
  reside on a non-RAID device.  A way to ensure that your system boots
  no matter what is, to create similar /boot partitions on all drives in
  your RAID, that way the BIOS can always load data from eg. the first
  drive available.  This requires that you do not boot with a failed
  disk in your system.

  With redhat 6.1 a patch to lilo 21 has become available that can
  handle /boot on RAID-1. Note that it doesn't work for any other level,
  RAID-1 (mirroring) is the only supported RAID level. This patch
  (lilo.raid1) can be found in
  dist/redhat-6.1/SRPMS/SRPMS/lilo-0.21-10.src.rpm on any redhat mirror.
  The patched version of LILO will accept boot=/dev/md0 in lilo.conf and
  will make each disk in the mirror bootable.

  Another way of ensuring that your system can always boot is, to create
  a boot floppy when all the setup is done. If the disk on which the
  /boot filesystem resides dies, you can always boot from the floppy.



  4.12.  Root filesystem on RAID

  In order to have a system booting on RAID, the root filesystem (/)
  must be mounted on a RAID device. Two methods for achieving this is
  supplied bellow. Because none of the current distributions (that I
  know of at least) support installing on a RAID device, the methods
  assume that you install on a normal partition, and then - when the
  installation is complete - move the contents of your non-RAID root
  filesystem onto a new RAID device.


  4.12.1.  Method 1

  This method assumes you have a spare disk you can install the system
  on, which is not part of the RAID you will be configuring.


  o  First, install a normal system on your extra disk.

  o  Get the kernel you plan on running, get the raid-patches and the
     tools, and make your system boot with this new RAID-aware kernel.
     Make sure that RAID-support is in the kernel, and is not loaded as
     modules.

  o  Ok, now you should configure and create the RAID you plan to use
     for the root filesystem. This is standard procedure, as described
     elsewhere in this document.

  o  Just to make sure everything's fine, try rebooting the system to
     see if the new RAID comes up on boot. It should.

  o  Put a filesystem on the new array (using mke2fs), and mount it
     under /mnt/newroot

  o  Now, copy the contents of your current root-filesystem (the spare
     disk) to the new root-filesystem (the array). There are lots of
     ways to do this, one of them is

      cd /
      find . -xdev | cpio -pm /mnt/newroot



  o  You should modify the /mnt/newroot/etc/fstab file to use the
     correct device (the /dev/md? root device) for the root filesystem.

  o  Now, unmount the current /boot filesystem, and mount the boot
     device on /mnt/newroot/boot instead. This is required for LILO to
     run successfully in the next step.

  o  Update /mnt/newroot/etc/lilo.conf to point to the right devices.
     The boot device must still be a regular disk (non-RAID device), but
     the root device should point to your new RAID. When done, run

      lilo -r /mnt/newroot

     complete with no errors.

  o  Reboot the system, and watch everything come up as expected  :)

  If you're doing this with IDE disks, be sure to tell your BIOS that
  all disks are ``auto-detect'' types, so that the BIOS will allow your
  machine to boot even when a disk is missing.


  4.12.2.  Method 2

  This method requires that you use a raidtools/patch that includes the
  failed-disk directive. This will be the tools/patch for all kernels
  from 2.2.10 and later.

  You can only use this method on RAID levels 1 and above.  The idea is
  to install a system on a disk which is purposely marked as failed in
  the RAID, then copy the system to the RAID which will be running in
  degraded mode, and finally making the RAID use the no-longer needed
  ``install-disk'', zapping the old installation but making the RAID run
  in non-degraded mode.


  o  First, install a normal system on one disk (that will later become
     part of your RAID). It is important that this disk (or partition)
     is not the smallest one. If it is, it will not be possible to add
     it to the RAID later on!

  o  Then, get the kernel, the patches, the tools etc. etc. You know the
     drill. Make your system boot with a new kernel that has the RAID
     support you need, compiled into the kernel.

  o  Now, set up the RAID with your current root-device as the failed-
     disk in the raidtab file. Don't put the failed-disk as the first
     disk in the raidtab, that will give you problems with starting the
     RAID. Create the RAID, and put a filesystem on it.

  o  Try rebooting and see if the RAID comes up as it should

  o  Copy the system files, and reconfigure the system to use the RAID
     as root-device, as described in the previous section.

  o  When your system successfully boots from the RAID, you can modify
     the raidtab file to include the previously failed-disk as a normal
     raid-disk. Now, raidhotadd the disk to your RAID.

  o  You should now have a system that can boot from a non-degraded
     RAID.



  4.13.  Making the system boot on RAID

  For the kernel to be able to mount the root filesystem, all support
  for the device on which the root filesystem resides, must be present
  in the kernel. Therefore, in order to mount the root filesystem on a
  RAID device, the kernel must have RAID support.

  The normal way of ensuring that the kernel can see the RAID device is
  to simply compile a kernel with all necessary RAID support compiled
  in. Make sure that you compile the RAID support into the kernel, and
  not as loadable modules. The kernel cannot load a module (from the
  root filesystem) before the root filesystem is mounted.

  However, since RedHat-6.0 ships with a kernel that has new-style RAID
  support as modules, I here describe how one can use the standard
  RedHat-6.0 kernel and still have the system boot on RAID.


  4.13.1.  Booting with RAID as module

  You will have to instruct LILO to use a RAM-disk in order to achieve
  this. Use the mkinitrd command to create a ramdisk containing all
  kernel modules needed to mount the root partition. This can be done
  as:

   mkinitrd --with=<module> <ramdisk name> <kernel>


  For example:

   mkinitrd --with=raid5 raid-ramdisk 2.2.5-22



  This will ensure that the specified RAID module is present at boot-
  time, for the kernel to use when mounting the root device.



  4.14.  Pitfalls

  Never NEVER never re-partition disks that are part of a running RAID.
  If you must alter the partition table on a disk which is a part of a
  RAID, stop the array first, then repartition.

  It is easy to put too many disks on a bus. A normal Fast-Wide SCSI bus
  can sustain 10 MB/s which is less than many disks can do alone today.
  Putting six such disks on the bus will of course not give you the
  expected performance boost.

  More SCSI controllers will only give you extra performance, if the
  SCSI busses are nearly maxed out by the disks on them.  You will not
  see a performance improvement from using two 2940s with two old SCSI
  disks, instead of just running the two disks on one controller.

  If you forget the persistent-superblock option, your array may not
  start up willingly after it has been stopped.  Just re-create the
  array with the option set correctly in the raidtab.

  If a RAID-5 fails to reconstruct after a disk was removed and re-
  inserted, this may be because of the ordering of the devices in the
  raidtab. Try moving the first ``device ...'' and ``raid-disk ...''
  pair to the bottom of the array description in the raidtab file.

  Most of the ``error reports'' we see on linux-kernel, are from people
  who somehow failed to use the right RAID-patch with the right version
  of the raidtools. Make sure that if you're running 0.90 RAID, you're
  using the raidtools for it



  5.  Testing

  If you plan to use RAID to get fault-tolerance, you may also want to
  test your setup, to see if it really works.  Now, how does one
  simulate a disk failure ?

  The short story is, that you can't, except perhaps for putting a fire
  axe thru the drive you want to ``simulate'' the fault on.  You can
  never know what will happen if a drive dies. It may electrically take
  the bus it's attached to with it, rendering all drives on that bus
  inaccessible. I've never heard of that happening though. The drive may
  also just report a read/write fault to the SCSI/IDE layer, which in
  turn makes the RAID layer handle this situation gracefully.  This is
  fortunately the way things often go.


  5.1.  Simulating a drive failure

  If you want to simulate a drive failure, then plug out the drive. You
  should do this with the power off.  If you are interested in testing
  whether your data can survive with a disk less than the usual number,
  there is no point in being a hot-plug cowboy here. Take the system
  down, unplug the disk, and boot it up again.

  Look in the syslog, and look at /proc/mdstat to see how the RAID is
  doing.  Did it work ?

  Remember, that you must be running RAID-{1,4,5} for your array to be
  able to survive a disk failure.  Linear- or RAID-0 will fail
  completely when a device is missing.

  When you've re-connected the disk again (with the power off, of
  course, remember), you can add the ``new'' device to the RAID again,
  with the raidhotadd command.


  5.2.  Simulating data corruption

  RAID (be it hardware- or software-), assumes that if a write to a disk
  doesn't return an error, then the write was successful. Therefore, if
  your disk corrupts data without returning an error, your data will
  become corrupted.  This is of course very unlikely to happen, but it
  is possible, and it would result in a corrupt filesystem.

  RAID cannot and is not supposed to guard against data corruption on
  the media. Therefore, it doesn't make any sense either, to purposely
  corrupt data (using dd for example) on a disk to see how the RAID
  system will handle that.  It is most likely (unless you corrupt the
  RAID superblock) that the RAID layer will never find out about the
  corruption, but your filesystem on the RAID device will be corrupted.

  This is the way things are supposed to work.  RAID is not a guarantee
  for data integrity, it just allows you to keep your data if a disk
  dies (that is, with RAID levels above or equal one, of course).



  6.  Reconstruction

  If you've read the rest of this HOWTO, you should already have a
  pretty good idea about what reconstruction of a degraded RAID
  involves. I'll summarize:

  o  Power down the system

  o  Replace the failed disk

  o  Power up the system once again.


  o  Use raidhotadd /dev/mdX /dev/sdX to re-insert the disk in the array

  o  Have coffee while you watch the automatic reconstruction running

     And that's it.

  Well, it usually is, unless you're unlucky and you RAID has been
  rendered unusable because more disks than the ones redundant failed.
  This can actually happen if a number of disks reside on the same bus,
  and one disk takes the bus with it as it crashes. The other disks,
  however fine, will be unreachable to the RAID layer, because the bus
  is down, and they will be marked as faulty.  On a RAID-5 where you can
  spare one disk, loosing two or more disks can be fatal.

  The following section is the explanation that Martin Bene gave to me,
  and describes a possible recovery from the scary scenario outlined
  above. It involves using the failed-disk directive in your
  /etc/raidtab, so this will only work on kernels 2.2.10 and later.


  6.1.  Recovery from a multiple disk failure

  The scenario is:

  o  A controller dies and takes two disks offline at the same time,

  o  All disks on one scsi bus can no longer be reached if a disk dies,

  o  A cable comes loose...

     In short: quite often you get a temporary failure of several disks
     at once; afterwards the RAID superblocks are out of sync and you
     can no longer init your RAID array.

  One thing left: rewrite the RAID superblocks by mkraid --force

  To get this to work, you'll need to have an up to date /etc/raidtab -
  if it doesn't EXACTLY match devices and ordering of the original disks
  this won't work.

  Look at the sylog produced by trying to start the array, you'll see
  the event count for each superblock; usually it's best to leave out
  the disk with the lowest event count, i.e the oldest one.

  If you mkraid without failed-disk, the recovery thread will kick in
  immediately and start rebuilding the parity blocks - not necessarily
  what you want at that moment.

  With failed-disk you can specify exactly which disks you want to be
  active and perhaps try different combinations for best results. BTW,
  only mount the filesystem read-only while trying this out... This has
  been successfully used by at least two guys I've been in contact with.



  7.  Performance

  This section contains a number of benchmarks from a real-world system
  using software RAID.

  Benchmarks are done with the bonnie program, and at all times on files
  twice- or more the size of the physical RAM in the machine.

  The benchmarks here only measures input and output bandwidth on one
  large single file.  This is a nice thing to know, if it's maximum I/O
  throughput for large reads/writes one is interested in.  However, such
  numbers tell us little about what the performance would be if the
  array was used for a news spool, a web-server, etc. etc.  Always keep
  in mind, that benchmarks numbers are the result of running a
  ``synthetic'' program. Few real-world programs do what bonnie does,
  and although these I/O numbers are nice to look at, they are not
  ultimate real-world-appliance performance indicators. Not even close.

  For now, I only have results from my own machine. The setup is:

  o  Dual Pentium Pro 150 MHz

  o  256 MB RAM (60 MHz EDO)

  o  Three IBM UltraStar 9ES 4.5 GB, SCSI U2W

  o  Adaptec 2940U2W

  o  One IBM UltraStar 9ES 4.5 GB, SCSI UW

  o  Adaptec 2940 UW

  o  Kernel 2.2.7 with RAID patches

  The three U2W disks hang off the U2W controller, and the UW disk off
  the UW controller.

  It seems to be impossible to push much more than 30 MB/s thru the SCSI
  busses on this system, using RAID or not. My guess is, that because
  the system is fairly old, the memory bandwidth sucks, and thus limits
  what can be sent thru the SCSI controllers.


  7.1.  RAID-0

  Read is Sequential block input, and Write is Sequential block output.
  File size was 1GB in all tests. The tests where done in single-user
  mode. The SCSI driver was configured not to use tagged command
  queuing.

        |            |              |             |              |
        |Chunk size  |  Block size  |  Read KB/s  |  Write KB/s  |
        |            |              |             |              |
        |4k          |  1k          |  19712      |  18035       |
        |4k          |  4k          |  34048      |  27061       |
        |8k          |  1k          |  19301      |  18091       |
        |8k          |  4k          |  33920      |  27118       |
        |16k         |  1k          |  19330      |  18179       |
        |16k         |  2k          |  28161      |  23682       |
        |16k         |  4k          |  33990      |  27229       |
        |32k         |  1k          |  19251      |  18194       |
        |32k         |  4k          |  34071      |  26976       |


  From this it seems that the RAID chunk-size doesn't make that much of
  a difference. However, the ext2fs block-size should be as large as
  possible, which is 4KB (eg. the page size) on IA-32.


  7.2.  RAID-0 with TCQ

  This time, the SCSI driver was configured to use tagged command
  queuing, with a queue depth of 8. Otherwise, everything's the same as
  before.



        |            |              |             |              |
        |Chunk size  |  Block size  |  Read KB/s  |  Write KB/s  |
        |            |              |             |              |
        |32k         |  4k          |  33617      |  27215       |

  No more tests where done. TCQ seemed to slightly increase write
  performance, but there really wasn't much of a difference at all.


  7.3.  RAID-5

  The array was configured to run in RAID-5 mode, and similar tests
  where done.

        |            |              |             |              |
        |Chunk size  |  Block size  |  Read KB/s  |  Write KB/s  |
        |            |              |             |              |
        |8k          |  1k          |  11090      |  6874        |
        |8k          |  4k          |  13474      |  12229       |
        |32k         |  1k          |  11442      |  8291        |
        |32k         |  2k          |  16089      |  10926       |
        |32k         |  4k          |  18724      |  12627       |


  Now, both the chunk-size and the block-size seems to actually make a
  difference.


  7.4.  RAID-10

  RAID-10 is ``mirrored stripes'', or, a RAID-1 array of two RAID-0
  arrays. The chunk-size is the chunk sizes of both the RAID-1 array and
  the two RAID-0 arrays. I did not do test where those chunk-sizes
  differ, although that should be a perfectly valid setup.

        |            |              |             |              |
        |Chunk size  |  Block size  |  Read KB/s  |  Write KB/s  |
        |            |              |             |              |
        |32k         |  1k          |  13753      |  11580       |
        |32k         |  4k          |  23432      |  22249       |


  No more tests where done. The file size was 900MB, because the four
  partitions involved where 500 MB each, which doesn't give room for a
  1G file in this setup (RAID-1 on two 1000MB arrays).



  8.  Credits

  The following people contributed to the creation of this
  documentation:

  o  Ingo Molnar

  o  Jim Warren

  o  Louis Mandelstam

  o  Allan Noah

  o  Yasunori Taniike

  o  Martin Bene


  o  Bennett Todd

  o  The Linux-RAID mailing list people

  o  The ones I forgot,  sorry   :)

  Please submit corrections, suggestions etc. to the author. It's the
  only way this HOWTO can improve.